国产2025中文天码字幕-国产3344视频在-国产3344视频在线观看-国产36页在线-国产3级在线观看-国产3区

產品中心

一步法人前列腺特異性膜抗原(PSMA)酶聯免疫吸附檢測試劑盒
ELK036ES
規格: 價格:
64T ¥2240.00
112T ¥3200.00

Overview

Product name: EasyStep Human PSMA(Prostate specific membrane antigen) ELISA Kit
Reactivity: Human
Alternative Names: Cell growth inhibiting protein 27; Cell growth-inhibiting gene 27 protein; FGCP; Folate hydrolase (prostate-specific membrane antigen) 1; Folate hydrolase 1
Assay Type: Sandwich
Sensitivity: 0.165 ng/mL
Standard: 40 ng/mL
Detection Range: 0.63-40 ng/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Signal Transduction; Cancer; Metabolism
Uniprot ID: Q04609
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PSMA, and the Human PSMA standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human PSMA. After TMB substrate solution is added, only those wells that contain Human PSMA and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PSMA in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
40.00 2.164 2.069
20.00 1.527 1.432
10.00 1.073 0.978
5.00 0.821 0.726
2.50 0.535 0.440
1.25 0.356 0.261
0.63 0.257 0.162
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PSMA and the recovery rates were calculated by comparing the measured value to the expected amount of PSMA in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 88-102% 95%
Heparin plasma(n=5) 80-92% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PSMA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-101% 87-98% 92-104% 82-96%
EDTA plasma(n=5) 85-94% 97-106% 79-91% 90-99%
Heparin plasma(n=5) 85-102% 81-96% 87-105% 83-92%

產品成分表

關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
主站蜘蛛池模板: 欧美mv| 国产一区视频在线观看免费 | 欧美日本一区二区视频在线播放 | 国产专区一区 | 综合色就爱涩涩涩综合婷婷 | 日韩精品免费一线在线观看 | 国产一区二区三区在线综合视频 | 亚洲成l人在线观看线路 | 中本亚洲欧美国产日韩 | 亚洲日本aⅴ精品一区二区在线 | 在线观看一级亚洲欧美观看 | 亚洲最新国产一区二区三区 | 东方影院 | 中文字幕无线码一区2025青青 | 国产一级大片在线观看 | 欧美亚洲日本国产黑白配 一级特黄高清aaa | 欧美色欧美亚洲高清在线观看 | 日本不无在线一区二区三区 | 日韩一区二区三区射精 | 国产天天看免 | 午夜福利不卡片在线播放免费 | 国产一级a毛一级a毛视频 | 精品一区二区三区在线观看视频 | 中文字幕在线不卡精品视频99 | 亚洲精品高清欧美 | 青青国产精品一区二区 | 国产线播放免费人成视频播放 | 中文天堂www | a级全黄试看30分钟国产 | 费精品国产一区国产精品剧情在线 | 精品国产香 | 亚洲无线码一区二区三区 | 午夜私人影院免费体验区 | 亚洲亚洲人成综合网络 | 一区二区三区四区电影 | 99电影网| 99精品视频在线观看婷婷 | 国产精品青青青高清在线 | 2025最新热门电视排行榜 | 国产精品边做奶水狂喷 | 国产亚洲精品午夜高清影院 |